The application data sheet is the official technical document for design and installation. Here is how to interpret it.
Every Global Building application data sheet is organised into seven information areas, following a standard layout.
Global Building logo and product line (FIRE, PAINT, CUPEL, CEM).
Element type (e.g. Non-load-bearing walls), fire resistance (e.g. EI 120), maximum height (h ≤ 12 m), boards used.
Dimensioned drawing of the build-up in mm, with numbered parts.
Numbered list: studs, tracks, boards, insulation, fixings.
EI/REI class achieved, test standard, I.G. report and (where applicable) EXAP report.
Technical description ready to copy into the project documents.
Global Building S.r.l. a Socio Unico company details and document revision.
Take a typical data sheet:
NON-LOAD-BEARING WALLS EI 120 · h ≤ 12 m · 2×FIREGUARD 13 mm
What the title tells us:
The Italian Fire Prevention Code (D.M. 3/08/2015) sets the performance levels required for the specific occupancy. Choose a data sheet with an EI/REI class equal to or higher than required.
Height, thickness, stud spacing, insulation type: they are all binding parameters for the validity of the classification.
The "Specification clause" section gives you a description ready for the project documents and tender specifications.
For the Italian Fire Brigade file (fire safety SCIA or renewal attestation), attach: the application data sheet, the I.G. classification report, the EXAP report (where applicable) and the declaration of correct installation.
Every solution in the Global Building catalogue has its own application data sheet available as a PDF download, together with the product technical data sheet, the BIM file (where available) and the I.G. classification report. You will find it all on the individual solution page, or in the Download Centre (filters by document type and product line, search by solution code or report number). To filter by fire resistance class, structure and section, use the solutions catalogue.
Technical support
If a value on the application data sheet is not clear, or your case differs from the certified configuration, our technical department can check it with you.