inspection hatch for self-supporting and membrane ceilings.

The hatch consists of: – a fixed perimeter frame made of aluminium angle profiles, nominal section 30x12 mm and nominal thickness 2 mm, fitted with 2 snap closures. – a door made with a calcium silicate and calcium sulphate board named FIREGUARD® 13, nominal thickness 12,7 mm and nominal weight 10,2 kg/m2, fixed to a perimeter frame made of aluminium angle profiles, with nominal section 30x12 mm and nominal thickness 2 mm. – a safety cable (from size 300x300 upwards). – an upper cover consisting of a semi-rigid mineral fibre panel treated on both sides with a layer of insulating coating. – the package includes packing strips for adaptation to different types of suspended ceiling.
The hatch shall be installed by cutting an opening in the ceiling equal to the frame dimensions (AxB) +162 mm. Line the internal vertical sides of the opening with FIREGUARD boards 80 mm high, to a depth of 51 mm, screwing the strips to the “C” profiles of the suspended ceiling framing. Simply lay the cover over the opening. Take the frame of the inspection hatch and insert it through the opening cut in the ceiling, fixing the outer frame with phosphated self-drilling screws to 60x25 mm angle brackets placed on each side of the opening. Insert the packing strips and, using Fireguard Compound, fill the joint between the frame and the suspended ceiling, including the screws. Once filling is complete, clean any residue off the outer frame, attach the safety cable and close the hatch.
The contents of this page are summarised from the official technical data sheet PDF, which remains the reference document.