Application
Structural Protection: Reinforced Concrete · R.C. Walls

| T (min) | 30’ | 60’ | 90’ | 120’ | 180’ | 240’ |
| t (mm) | 42 | 56 | 65 | 68 | 57 | 17 |
Supply and installation of cladding for reinforced concrete walls with REI 30/60/90/120/180/240 fire resistance, made with FIREGUARD® boards, thickness… mm (see tables), maximum dimensions 1200x2000 mm, made of calcium silicates and sulphates, asbestos-free, produced by lamination with factory-controlled drying, in reaction-to-fire class A1 (non-combustible), in accordance with assessment report ITB 03061-A1/25 according to EN 13381-3.
The boards will be applied with metal expansion anchors, 9 mm diameter, 40 mm long, at 500 mm centres. The finishing of the joints and anchor heads will be carried out with FIREGUARD COMPOUND filler.