Application
Vertical Compartmentation · High Walls

| Height (metres) | 6 | 8 | 10 | 11,5 | 12 |
| Boxed “C” profile (mm) | 150 x 50 x 0,6 | 150 x 50 x 0,8 | 150 x 50 x 0,6 | — | — |
| Centres (mm) | 2000 | 2000 | 1000 | — | — |
| Load-bearing tubular profile (mm) | 100 x 100 x 2 | 100 x 120 x 3 |
Supply and installation of an interior partition with fire resistance EI 120, made with two FIREGUARD®13 boards per side, 12,7 mm thick, made of calcium silicates and sulphates, asbestos-free, produced by lamination with factory-controlled drying, in class A1 (non-combustible) reaction to fire, in accordance with classification report I.G. 380050/4091FR and Technical File 399950. The boards will be installed horizontally with phosphated self-drilling screws, diameter 3,5 mm, length 60 mm, to the load-bearing metal profiles and
positioned at 2000 mm centres, inserted into “U” tracks 100x40x2,0 mm placed at floor and ceiling. The studs will be fully protected on all four vertical sides with FIREGUARD®13 strips screw-fixed with phosphated self-drilling screws, dia. 3,5 mm, length 60 mm. The joints and screw heads will be finished with FIREGUARD COMPOUND filler.
| 100 x 180 x 3 |
| 100 x 200 x 3 |
| 150 x 200 x 3 / 100 x 250 x 3 |
| Centres (mm) | 2000 | 2000 | 2000 | 2000 | 2000 |
Downloads reserved for registered users with a confirmed email address. Register · Sign in