Application
Vertical Compartmentation · Double-Frame Walls

Supply and installation of a vertical wall with fire resistance EI 180, built with two plasterboard finishing boards and three FIREGUARD® 18 boards, thickness 18,0 mm, made of calcium silicates and sulphates, asbestos-free, produced by lamination with factory-controlled drying, in reaction-to-fire class A1 (non-combustible), in accordance with classification report I.G. 403514/4299FR and Technical File. The boards will be installed using phosphated self-drilling screws diam. 3,5 mm,
length 25 mm at 600 mm spacing for the inner layer, length 35 mm at 600 mm spacing for the intermediate layer, length 55 mm at 250 mm spacing for the outer layer, to a double metal framing of “C” profiles 75x50x0,6 mm placed at 600 mm centres and inserted into “U” tracks 75x40x0,6 mm, placed at floor and ceiling on both sides of the wall. The plasterboard boards serve a finishing function only and are not required for fire protection purposes.