inspection hatch for REI 180 suspended ceilings in cement-matrix silicates

The hatch consists of: – a fixed perimeter frame made of aluminium angle profiles, nominal section 30x12 mm and nominal thickness 2 mm, fitted with 2 snap closures. – a door consisting of a perimeter frame made of aluminium angle profile, nominal section 30x12 mm and nominal thickness 2 mm. Infill, nominal thickness 13 mm, made with 1 cement-matrix silicate board named NAPER S 12, nominal thickness 12 mm and nominal weight 14,3 kg/m2, fixed to the frame with phosphated steel self-drilling screws. – invisible snap closures and safety cable.
The hatch is installed by cutting an opening in the suspended ceiling measuring the size of the frame +85 mm and fitting the 50x27x0,6 mm “C” profiles around the opening, at a distance of 60 mm from the opening itself. Line the internal vertical sides of the opening with one layer of NAPER S 12 boards, 12 mm thick, to a height of 50 mm, screwing the boards to the 50x27x0,6 mm “C” profiles. Position a cover made of one layer of NAPER S 12 boards and rock mineral wool 40 mm thick, density 60 kg/m3, simply resting on the opening. Take the inspection hatch, insert it through the opening cut in the suspended ceiling and fix the outer frame with phosphated self-drilling screws. Seal the perimeter of the frame to the suspended ceiling with Fireguard Compound, including the screws. Once the sealing is complete, clean any residues off the outer frame, attach the safety cable and close the hatch.
The contents of this page are summarised from the official technical data sheet PDF, which remains the reference document.