SEISMIC JOINT “FIREGUARD 13”
Application
Seismic Joints · Anti-Seismic Joint With Induced Mov. Anti-Seismic Joint ·Fireguard 13·

| Joint width | Joint orientation | Supporting construction | Classification | Certificate |
| 0 mm ≤ x ≤ 400 mm | Horizontal / vertical | Rigid floor slab / walls density 550 kg/m³ · thickness ≥ 150 mm | EI 120 H-M100-B-W0 to 400 | I.G. 391896/4199FR |
Supply and installation of SEISMIC JOINT “FIREGUARD 13” for the protection of expansion joints in floor slabs with movement capability up to 100%, with fire resistance EI 120 H-M100-B-W 0 to W 400, consisting of a triple layer of calcium silicate and sulphate boards, thickness 12,7 mm each, total thickness 38,1 mm and width 600 mm, so as to provide a side overlap onto the floor slab of ≥100 mm. The boards shall be installed with staggered joints, fixed to each other with steel screws, and to the supporting construction along the opposite longitudinal edge with self-drilling screws, or screws with plugs, size 5x120 mm, at 300 mm centres.
At the contact point between the SEISMIC JOINT “FIREGUARD 13” and the moving part of the floor slab there is an intumescent gasket, size 30x1,5 mm, called “GB-T”, inserted into a dedicated housing formed by milling. To keep the system in contact with the floor slab while leaving it free to move, 30x30x1,5 mm “C” metal profiles must be used, fixed to the floor slab on one side and free to move on the other by means of a sliding trolley. The supporting profiles shall be placed at 1000 mm centres.